Abstract [eng] |
The topic of Master final work - structural prodject part of multifunctional building. The first floor is 26.6 m. wide and 32.6 m. length. The building is twenty-six floors. Projected building site - 60600 m2. The final work consists of the following components: 1. Construction regulation and legal conditions part where the construction process is identified in legal acts. 2. Architectural part where architectural solutions are discussed and the thermal resistance of the roof is calculated. 3. Structural part where the reinforced concrete column, steel columns, driven pile foundation, reinforced concrete beam and slab are calculated. 4. Technological, organizational and economic part, where the princes of the columns are compared and technology of the economical, reinforced column is described. 5. Safety and environmental protection part, which specifies the process of construction work safety and environmental protection. 6. The research part, which is examined how wind works to building, according to building technical regulation and acording to Eurocode. These constructions were calculated: driven pile foundation, reinforced column, steel column, reinfoced pre-stressed hollow slab and reinforced concrete beam. Also an economical comparison was made of two types of columns and the cost – effective option was explicitly specified. |