Title |
Echospektriniai audinių įvertinimo metodai / |
Another Title |
Echospectral methods of tissue evaluation. |
Authors |
Žakauskas, M ; Mačiulis, A ; Kopustinskas, A ; Paunksnis, Alvydas ; Kurapkienė, Skaidra ; Jegelevičius, D |
Full Text |
|
Is Part of |
Elektronika ir elektrotechnika.. Kaunas : Technologija. 2004, Nr. 7, p. 70-73.. ISSN 1392-1215. eISSN 2029-5731 |
Keywords [eng] |
tissues ; ultrasonography ; methods |
Abstract [eng] |
Development techniques of estimation structure of tissues is one of the main task in medical diagnostics. At present time for this purpose is widely using qualitative ultrasound imaging technique, based on the evaluation of the A, B, M scans. In this case significant part of valuable information, existing in echosignal is inaccessible. New technique for registration, experimental investigation ultrasound radiofrequency signals from tissue are presented in this paper. Echospectral methods allow to get additional information about tissue structure. It is shown mean spectral frequency is higher for tumour tissue. |
Published |
Kaunas : Technologija |
Type |
Journal article |
Language |
Lithuanian |
Publication date |
2004 |
CC license |
|