Title Nusistovėjusios srovės porėtame biojutiklio elektrode kompiuterinis modeliavimas /
Another Title Computer simulation of the steady state currents at enzyme doped carbon paste electrodes.
Authors Ivanauskas, Feliksas ; Laurinavicius, Valdas ; Šimkus, Remigijus ; Kaunietis, Irmantas
DOI 10.15388/LMR.2005.29254
Full Text Download
Is Part of Lietuvos matematikos rinkinys.. Vilnius : Matematikos ir informatikos institutas. 2005, t. 45, spec. nr, p. 481-485.. ISSN 0132-2818. eISSN 2335-898X
Keywords [eng] reaction-diffusion ; modelling ; amperometric biosensors ; porous electrode
Abstract [eng] Reaction-diffusion in porous enzyme-doped carbon paste electrode has been analyzed. The plate-gap model of such electrode has been proposed. The steady state current was calculated for the wide range of given parameters. The apparent parameters (apparent maximal currents and apparent Michaelis constants) of the modelled electrode were calculated. Relationships between apparent and given parameters were derived.
Published Vilnius : Matematikos ir informatikos institutas
Type Journal article
Language Lithuanian
Publication date 2005
CC license CC license description