Title EKG derivacijų integralinės koreliacinės dimensijos vertinimas /
Another Title Evaluation of dimension of integral correlation for ECG.
Authors Navickas, Z ; Statkus, V ; Vainoras, A ; Gargasas, L
Full Text Download
Is Part of Elektronika ir elektrotechnika.. Kaunas : Technologija. 2005, Nr. 5, p. 67-69.. ISSN 1392-1215. eISSN 2029-5731
Abstract [eng] To investigate complexity of ECG data, was used dimension of integral correlation by Kolmogorov. Data array was formatted from twelve synchronically registered ECG leads. Length of registration – 10sec, discretization rate 500Hz. Correlation dimension was computed for different leads , with different loads, for both sex and with given extrasystoles. As results showed, there are some essential differences between complexity of leads for both sex, when some physical loads were being performed. The correlation dimension for studied leads with extrasystole was higher for all leads.
Published Kaunas : Technologija
Type Journal article
Language Lithuanian
Publication date 2005
CC license CC license description