Title Evaluation of the thermal insulation performance of the ground floorof an A++ class public building using the saw method /
Authors Aviža, Donatas
Full Text Download
Is Part of Taikomieji tyrimai studijose ir praktikoje – Applied research in studies and practice.. Panevėžys : Panevėžio kolegija. 2023, Vol. 19, No.1, p. 39-44.. ISSN 2029-1280. eISSN 2669-0071
Keywords [eng] thermal insulationlayer ; ground floor ; nearly zero-energy public building ; SAW method
Abstract [eng] This paper investigates the Simple Added Weighting (SAW) method for evaluating the thermal insulation performance of the ground floor of an A++ class public building. Four alternative insulation materials (ŠILPUTA EPS100; FF-EPS100S; FINNFOAM F-200; PAROC GRS 20) were evaluated on the basis of six criteria: the compressive strength up to 10% deformation, the design value of thermal conductivity coefficient, the thickness of the thermal insulation layer, the cost (Q4 2023), the global warming potential (GWP)and the long-term water absorptionof the insulation material. The results of the empiricalresearch indicate that FINNFOAM F-200is the most effective thermal insulation material for the ground floor insulation of a nearly zero-energy public building. The highest relative performance score (0.87) was achieved by this material. Rock wool PAROC GRS 20is the least effective (0.51 points) alternative (from the four tested materials).
Published Panevėžys : Panevėžio kolegija
Type Journal article
Language Lithuanian
Publication date 2023
CC license CC license description