Title |
Experimental and numerical study of healing effect on delamination defect in infusible thermoplastic composite laminates / |
Authors |
Griskevicius, Paulius ; Spakauskas, Kestutis ; Mahato, Swarup ; Grigaliunas, Valdas ; Raisutis, Renaldas ; Eidukynas, Darius ; Perkowski, Dariusz M ; Vilkauskas, Andrius |
DOI |
10.3390/ma16206764 |
Full Text |
|
Is Part of |
Materials.. Basel : MDPI. 2023, vol. 16, iss. 20, art. no. 6764, p. 1-16.. ISSN 1996-1944 |
Keywords [eng] |
cohesive zone modelling ; compression-after-impact ; delamination ; fiber reinforced thermoplastic composite ; thermal healing |
Abstract [eng] |
The integrity of delaminated composite structures can be restored by introducing a thermally-based healing effect on continuous fiber-reinforced thermoplastic composites (CFRTPC). The phenomenon of thermoplastics retaining their properties after melting and consolidation has been applied by heating the delaminated composite plates above their glass transition temperature under pressure. In the current investigation, the composite is comprised of Methyl methacrylate (MMA)-based infusible lamination resin combined with benzoyl peroxide initiator, which polymerizes into a Polymethyl methacrylate (PMMA) matrix. For the reinforcement, unidirectional 220 gr/m2 glass filament fabric was used. Delamination damage is artificially induced during the fabrication of laminate plates. The distributed delamination region before and after thermally activated healing was determined by using non-destructive testing with active thermography. An experimental approach is employed to characterize the thermal healing effect on mechanical properties. Experimentally determined technological parameters for thermal healing have been successfully applied to repair delamination defects on composite plates. Based on the compression-after-impact (CAI) test methodology, the intact, damaged, and healed composite laminates were loaded cyclically to evaluate the healing effect on stiffness and strength. During the CAI test, the 3D digital image correlation (DIC) technique was used to measure the displacement and deformation fields. Experimental results reveal the difference between the behavior of healed and damaged specimens. Additionally, the numerical models of intact, damaged, and healed composite laminates were developed using the finite element code LS-Dyna. Numerical models with calibrated material properties and tie-break contact constants provide good correlation with experimental results and allow for the prediction of the mechanical behavior of intact, damaged, and healed laminated plates. The comparison analysis based on CAI test results and modal characteristics obtained by the 3D Laser Doppler Vibrometer (Polytec GmbH, Karlsbad, Germany) proved that thermal healing partially restores the mechanical properties of damaged laminate plates. In contrast, active thermography does not necessarily indicate a healing effect. |
Published |
Basel : MDPI |
Type |
Journal article |
Language |
English |
Publication date |
2023 |
CC license |
|